Project Description
12kV/24kV/33kV Auto-recloser
The manual operated or automatic remote-controlled Auto-recloser (Vacuum) (Or vacuum circuit breaker) is an outdoor distribution equipment with rated voltage of 12kV/24kV/33kV and three-phase AC of 50/60Hz.
It is mainly used to open and close load current, overload current and short circuit current in power system.
It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated.
The circuit breaker has the characteristics of small volume, light weight, anti-condensation, free maintenance and so on.
It can adapt to the harsh weather conditions and pollution environment.
The body part of Auto-recloser (Vacuum) (Or vacuum circuit breaker) is composed of a conductive circuit, an insulating system, a seal and a housing. The overall structure is three-phase cabinet type.
The conductive circuit is composed of an incoming and outgoing conductive rod, an incoming and outgoing insulation support, a conductive clamp, a soft connection and a vacuum arcing chamber.
The mechanism is electric energy storage, electric opening and closing, and has manual function.
The whole structure is composed of closing spring, energy storage system, over current release device, opening and closing coil, manual opening and closing system, auxiliary switch, energy storage indicator and other components.
The working principle of vacuum circuit breaker is different from that of other circuit breakers. There is no conductive medium in vacuum, which makes the arc extinguish quickly.
Therefore, the distance between the dynamic and static contacts of the circuit breaker is very small.
Sketch Drawing for Model ZW32-12

Sketch Drawing for Model ZW32-12F (with CT)

Sketch Drawing for Model ZW32-24

Sketch Drawing for Model ZW32-33

Technical Parameters
| Specification | Unit | Value |
| Rated voltage | kV | 30 – 40.5 |
| Max. working voltage | kV | 40.5 |
| Rated current, not less than | A | 630A / 1250A /1600A |
| Rated breaking current, not less than | kA | 20 |
| Electrical dynamic withstand current | kA | 51 |
| Operation times | 30000 | |
| Heating withstand current (during 3 seconds/this parameter must not be as 1 sec), not less than | kA | 20 |
| Open, close reserve, not less than
– By rated current, Close-Open action – By breaking current, Close-Open action |
30000
25 |
|
| Breaking own period, not more than | ms | 45 |
| Full breaking period, not more than | ms | 55 |
| Close own period, not more than | ms | 60 |
| Testing voltage of lightning impulse | kV | 190 |
| 1 min testing voltage by voltage with production frequency | kV | 95 |
| Cycle of recloser | O-0.02S-C-0.1S | |
| Max amount of close and open cycle within 1 hour, not less than | 100 | |
| Ambient environmental condition performance | Dedicated to work for outdoor and cold weather | |
| Upper limit of ambient relative moisture when air temperature is at 25°C | 100% | |
| Ambient environmental min temperature | °C | -50 |
| Ambient environmental max temperature | °C | +55 |
| Environmental condition, not less than | m | 1500 m a.s.l |
| Protection degree of drive external main body | IP54 | |
| Penetration length of external insulating, mm, not less than | 1700 | |
| Permissible environmental wind amount when no icing-not more than | m/s | 40 |
| Permissible environmental wind amount of wire iced period (Icing wall thickness is till 20 mm), not more than | m/s | 15 |
| Specification/Model |
ZW32-12 |
ZW32-12F (with CT) |
ZW32-24 |
| Rated Voltage |
12kV |
12kV |
24KV |
| Rated Current |
630A/1250A |
630A/1250A |
630A, 1250A |
| Frequency |
50Hz |
50Hz |
50Hz |
| Short circuit break current |
20kA/25kA |
20kA/25kA |
20kA |
| Short-time Withstand Current |
20kA/25kA |
20kA/25kA |
20kA |
| Peak Withstand Current |
50kA/63kA |
50kA/63kA |
50kA |
| Mechanical Life (operations) |
10000 |
10000 |
10000 |
| Power Frequency Withstand Voltage (Dry) |
42kV/48kV |
42kV/48kV |
65kV |
| Lightning impulse withstand voltage |
75kV/85kV |
75kV/85kV |
145kV |